Opened 8 years ago

Closed 8 years ago

Last modified 6 years ago

#492 closed bug (fixed)

Retainer and biographical profiling with STM

Reported by: simonmar Owned by: simonmar
Priority: normal Milestone: 6.4.2
Component: Runtime System Version: 6.4.1
Keywords: Cc:
Operating System: Unknown/Multiple Architecture: Unknown/Multiple
Type of failure: Difficulty: Unknown
Test Case: Blocked By:
Blocking: Related Tickets:

Description (last modified by simonmar)

Retainer profiling (-hr) and biographical profiling
(-hb) do not currently work with STM, they result in
errors like this:

internal error: Invalid object in isRetainer(): 67

Change History (4)

comment:1 Changed 8 years ago by simonmar

  • Description modified (diff)
  • Milestone set to 6.4.2

comment:2 Changed 8 years ago by simonmar

  • Architecture set to Unknown
  • Difficulty set to Unknown
  • Operating System set to Unknown
  • Resolution changed from None to fixed
  • Status changed from assigned to closed

fixed in 6.4.2

comment:3 Changed 6 years ago by simonmar

  • Architecture changed from Unknown to Unknown/Multiple

comment:4 Changed 6 years ago by simonmar

  • Operating System changed from Unknown to Unknown/Multiple